Current Consumption for a Custom Segment LCD Module

The standard current draw of a static LCD module at normal operating temperature is between 1.2uA/squre cm to 1.5uA per square cm.  The required current is higher for a wide temperature LCD module.  This does not include the power required for a LED backlight or EL backlight.

In most cases, when a customer is looking for a ultra low power LCD display, they use a segmented module only. This glass only solution includes a static display or a multiplex custom LCD design.

Focus display LCD’s have the following options.

  • 3V LCD driving voltage of 5V LCD driving voltage.
  • Normal temperature or wide operating temperature
  • TN, STN or FSTN
  • Parallel interface and SPI interface

Contact Focus Displays for design assistance on your custom display or modified LCD requirements.